Before the power generator runs, a series of preparatory work is required to ensure that it can start up normally and run stably in emergency situations. The following are detailed preparation steps:
1. Safety inspection of the power generator: Conduct a safety inspection to confirm that there are no debris around the generator set, good ventilation, no flammable or explosive materials, and that all components of the generator set, such as the fuel tank, filter, cooling system, etc., have no leaks.
2. Cleaning work: Clean the power generator, remove dust and oil stains to ensure that the generator set operates in a good working environment. Pay special attention to cleaning the air filter to ensure smooth air intake.
3. Oil inspection: Check whether the diesel in the fuel tank is sufficient and whether the quality of the diesel meets the requirements for use. At the same time, it is also necessary to check the oil level and quality of the lubricating oil to ensure that the lubrication system can work properly.
4. Generator battery inspection: Check if the battery is fully charged, if the electrolyte level is normal, and if the battery connection is secure. If the battery is found to be low or the electrolyte level is too low, it should be charged or the electrolyte should be added in a timely manner.
5. Control system inspection: Check the control system of the generator, including start-up control, protection control, parallel control, etc., to ensure that all control systems can work properly. At the same time, check whether the alarm system and display system are normal, so that any abnormal situations can be detected and dealt with in a timely manner.
6. Inspection of the power generator cooling system: Check the cooling system, including the coolant level, whether the radiator is clean, and whether the fan is working properly. Ensure that the generator set can dissipate heat and prevent overheating during operation.
7. Check the exhaust system of the power generator: Check if the exhaust system is unobstructed, if there are any blockages or leaks. Ensure that the exhaust gas can be smoothly discharged during the operation of the generator set without causing damage to the generator set.
8. Test start: After confirming that the above checks are correct, start the generator test. Observe whether the generator set can start normally, whether each component can work properly, and record relevant data. If there are any abnormal situations, they should be promptly handled and recorded.
9. Maintenance of the power generator: According to the maintenance manual of the generator, perform necessary maintenance work, such as changing oil, cleaning filters, etc. Ensure that the generator set operates in good technical condition.