The hospital backup generator is a lifeline power supply system for medical institutions, and its importance, design standards, and operational requirements are far higher than those for ordinary commercial or industrial use.
I. Characteristics of Hospital Backup Generators
Hospital backup generators are part of an emergency power system, providing uninterrupted electricity to life-support equipment. Their design complies with strict regulations and features core characteristics such as automatic fast switching, high-capacity redundancy, and regular load testing, making them a crucial lifeline for ensuring medical safety.
II. Huaquan Power is a professional hospital backup generator manufacturer in China.
Huaquan Power Company was established in 2010. Its business spans multiple fields, including power generation equipment, new energy storage equipment, high and low voltage complete sets of equipment, and power engineering. The company has created three major brands: "HQ-POWER," "HUAQUAN," and "Huaquan." Currently, the company has developed into a strong global brand in the power industry, with cumulative global sales exceeding 1 million units.
III. Advantages of Hospital Backup Generators
1. Lifeline Protection: Hospital backup generators provide uninterrupted power to operating rooms and life-support equipment, directly impacting patient safety.
2. Highly Reliable System: With automatic fast switching (typically <10 seconds) and often using an 'N+1' redundancy design, a single unit failure can still maintain full load operation.
3. Regulatory Standards: Strictly compliant with mandatory medical standards, they are legally required facilities for hospital operation.
4. Extended Endurance: Hospital backup generators are equipped with large fuel storage systems, ensuring continuous power supply for over 72 hours to handle prolonged disasters.
5. Proactive Reliability: Regular load testing and monitoring are enforced to ensure the system is always in optimal standby condition.
IV. Precautions for Storing Hospital Backup Generators
1. Environment and Location for Storing Hospital Backup Generators
Dedicated Room: Fireproof independent space, away from flammable and explosive materials.
Ventilation and Heat Dissipation: Ensure smooth air intake and exhaust, and direct exhaust smoke to a safe outdoor location.
Waterproof and Moisture-proof: The generator room should be dry, above flood level, to prevent equipment rust.
Ease of Maintenance: Leave enough operational space around the backup generator, with passages allowing easy equipment access.
2. System Status Checks for Hospital Backup Generators
Sufficient Fuel: Fuel storage should support at least 72 hours of full-load operation, with regular fuel quality checks and water drainage.
Battery: Equipped with a float charger, kept fully charged, and regularly checked as this is the most common failure point.
Standby Mode: Control switch set to “Automatic”, coolant preheating device always on.
Pipeline Unobstructed: Check fuel, coolant pipelines, and valves to ensure no leaks or blockages.
3. Management and Maintenance of Hospital Backup Generators
Regular Testing of Hospital Backup Generators:
Weekly: No-load automatic start test.
Monthly: Load test (≥30% load) for more than 30 minutes to verify actual power supply capacity.
Labeling and Records: Clear labeling of all hospital backup generators, with complete and traceable testing and maintenance records.
Person in Charge: Generator room locked, managed by designated personnel, who must be trained and familiar with operational procedures.
V. Q&A on Hospital Backup Generators
1. What is a "loaded test" for a hospital backup generator?
Simulate a power outage every month, allowing the hospital backup generator to operate at least 30% of its rated load, to verify its actual power supply capability.
2. What is "N+1" redundancy for hospital backup generators?
Multiple hospital backup generators are installed so that even if one fails, the others can still meet all critical load requirements, enhancing reliability.
3. How is the power of a hospital backup generator determined?
It is based on detailed calculations of all critical loads, with sufficient margin, and must be carried out by a professional design institute.
Hospital backup generators are the highest-level emergency power systems for medical institutions, specifically designed to provide uninterrupted and reliable electricity to equipment and critical areas within the hospital that directly affect patients' lives in the event of a municipal power outage. Users should select a suitable hospital backup generator based on their specific operational needs.
More information about Hospital Backup Generator: https://fadianjipower.com/
Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD